IoT product and technology solution provider

RS485 CL2 Sensor Industrial Grade Environmental Monitoring

The RS485 chlorine gas transmitter designed by our company has the characteristics of fast response, high sensitivity, and strong anti-interference ability. Equipped with high-performance chlorine gas sensors and microprocessors, it has the characteristics of high detection accuracy, stable performance, and low power consumption. Suitable for chlorine gas concentration monitoring in industrial safety, environmental monitoring, industrial production and other places.

This device adopts a wide voltage 50-28V DC power supply, 485 signal output, standard ModBus RTU communication protocol, can set ModBus address, can change baud rate, and has a communication distance of up to 2000 meters.

  • Model No.:

    LW311-Cl2(RS485)
  • Use:

    Detect the content of gas Cl2
  • Power Supply:

    5~28VDC
  • LoRaWAN Mode:

    OTAA Class A/C
  • Certificates:

    CE,ROHS,FCC,ISO and 11 patents certifications
  • Customized Support:

    OEM, ODM
  • Warranty:

    1 Year
  • Product Detail

RS485 CL2 Sensor Industrial Grade Environmental Monitoring



Core Advantages for Industrial Environmental Monitoring

  • Long-Distance Stable Transmission:

1.RS485 bus enables reliable long-distance data transmission.

2.Anti-interference design ensures signal stability in complex industrial settings.

3.Supports multi-node networking for large-scale environmental monitoring deployment.

  • Ultra-Low Power Consumption & Long Battery Life:

1.Equipped with low-power chip and smart sleep mode.

2.Extended battery life for hassle-free long-term operation.

3.Customizable working modes ideal for unmanned monitoring scenarios.

  • Multi-Dimensional Alarm Mechanism:

1.Multi-level threshold alarm system for comprehensive risk management.

2.Real-time alarm notification and automatic linkage with control systems.

3.Flexible local and remote parameter adjustment for diverse application needs.

  • Industrial-Grade Protection for Harsh Environments:

1.High-level dustproof and waterproof protection for tough working conditions.

2.Wide temperature tolerance adapts to extreme environmental fluctuations.

3.Durable housing and sealed connectors for enhanced corrosion and wear resistance.

  • Data Encryption & High Reliability:

1.Full-digital encryption technology safeguards data security during transmission.

2.High-precision sensing components deliver accurate and consistent environmental data.

3.Offline data caching function prevents data loss and ensures complete data records.


RS485 Gas Hydrogen Sulfide(Cl2) Sensor :

Precise measurement
Stable performance
Low energy consumption

This (Cl2) sensor is suitable for long-term use. 



Cl2 Sensor Specification:



Item

Content

Power Supply

5~28VDC

Weight

120g

Usage Environment

Temperature: -20℃~50℃

Humidity: 15%~ 90% RH without condensation

NOTE:It is not recommended to stay in a high humidity environment for more than half a month

Measuring Principle

Electrochemical Principle

Measuring Range

CL2: 0~20 ppm

Resolution and Accuracy

CL2: 0.1 ppm, 10%

Temp.and Humi. Sensor

Temp Range:-40~+80 ℃

Accuracy:±0.3 ℃

Humi Range:0~99.9 %RH

Sensor Lifespan

< 2 years

Data update time

2s


Packaging:


Single gross weight: 0.600 KG

Single package size: 23X20X5 cm




Product Description: 












Frequently Asked Questions:


1.Q: Where is this sensor suitable for installation, and which areas should be avoided?

A: It is preferred to install the sensor 1-3 meters downwind from potential chlorine leakage points such as chlorine storage equipment and pipeline joints.

The installation height should be level with or slightly lower than the leakage source (to align with chlorine’s higher density than air, ensuring rapid detection of accumulated gas).


2.Q: How long does the sensor’s battery last? What should I do if the battery drains quickly?

A: Note: This sensor (with RS485 communication) is typically powered by an external power supply (not battery-powered). 

If you are using a battery-powered version, equipped with a low-power design, its battery life can reach several years under regular data reporting frequency. 

However, the actual lifespan is affected by factors such as communication load.


3.Q: What are the common reasons for intermittent data transmission of the sensor?

A: In addition to poor RS485 wiring contact (e.g., loose A/B line connections), intermittent transmission may also be caused by excessive distance between the sensor and the RS485 host (exceeding the effective communication distance of RS485), or excessive number of devices on the same bus (leading to signal attenuation), or electromagnetic interference near the bus (e.g., proximity to high-power electrical equipment).

You can try adjusting the wiring (reconnect A/B lines firmly), reducing the number of devices on the bus, or moving the bus away from interference sources first. 

If the problem persists, please consult us for customized RS485 bus planning and optimization solutions.



Application


The High precision Cl2 sensor also widely used for gas monitoring of Chemical production, Ward monitoring, Vegetable greenhouse, Livestock and poultry farms, Tunnel monitoring, Cold chain logistics vehicle, Cold storage monitoring, Biosafety laboratory.


applications of NO2 sensor


Certifications:


1. Company Background:As a leading gas sensor manufacturer and exporter in China, we have over 10 years of industry expertise and a strong reputation for reliable, high-quality products.

2.Certified Product: Our chlorine (Cl₂) sensor line has obtained CE and RoHS certifications.

3.Value of Certifications:

(1)Validates that our products meet strict European standards for safety, health, and environmental protection.

(2)Reflects our commitment to delivering solutions that align with global market requirements.

(3)Benefits of Certification: This certified status allows our Cl₂ sensors to integrate smoothly into applications across regions worldwide, providing customers with both performance assurance and regulatory peace of mind.



Production Process:



factory of gas sensor manufacturer



Why choose us:


1. Strong R & D: 30+ Senior experts and highly educated personnel formed a R & D team, heavy investment, master a number of core technologies and patents.
2. Professional and effective solutions: for smart environmental protection, agriculture and other fields, to provide customized compound networking solutions.
3. Full range of products: covering the whole industry chain products from data collection to platform services to meet diverse needs.
4. Excellent quality: we have perfect quality control system, strictly quality control each production link, low defective rate. 
5. Good service: 7×24 hours fast response, Professional pre-sale, sale, after-sales team support.

Want to know about this product?

SEND A MESSAGE
Get A Free Quote

If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.

Related Products
RS485 Ethylene C2H4 Sensor Module - 4-20mA Output for Agricultural Industrial Ethylene Detector High Precision RS485
ZONEWU RS485 ethylene (C2H4) sensor is a type of sensor used to monitor ethylene gas. Supports RS485 interface and standard ModBusRTU protocol. Equipped with high-performance ethylene sensors and microprocessors, it has the characteristics of high detection accuracy, stable performance, and low power consumption. It can preset upper and lower threshold values based on the environment and actively report data anomalies. Widely used in industrial safety, agricultural production, environmental protection and other scenarios.
ZONEWU Phosphine Gas Detector High precision RS485 Phosphine(PH3) Gas Sensor
This RS485-type phosphine (PH3) sensor adopts the electrochemical principle and supports the ModBusRTU protocol. With a measuring range of 0-1000ppm and a resolution of 0.1ppm, it boasts high detection accuracy and stable performance. Powered by 5-28VDC wide voltage, it features a wall-mounted waterproof design suitable for harsh environments and can proactively report data anomalies. It is widely used in phosphine monitoring scenarios such as industrial safety, agricultural production and environmental protection.
CO₂ Sensor, Gas Detection, Environmental Monitoring High Sensitivity RS485 CO₂ Gas Concentration Monitoring Sensor
This is a high-precision CO₂ gas concentration sensor, suitable for scenarios such as indoor environmental monitoring, fresh air systems, and agricultural greenhouses. It can detect the CO₂ concentration in the air in real time and output accurate data, featuring fast response speed, strong stability, and excellent anti-interference ability. It supports multiple signal output methods, facilitating integration with various devices and helping users keep track of the environmental gas quality.
ZONEWU Oxygen Gas Detector Professional RS485 Long Distance Oxygen(O2) Gas Sensor
Our RS485-type O2 temperature and humidity sensor boasts rapid response, high sensitivity, and strong anti-interference. Calibrated via multi-stage standard gas and unique compensation algorithms, it offers long service life (≥24 months), high precision (O2: ±2%FS, temp: ±0.5℃, humidity: ±3%RH) and stability. With 10-30V DC wide voltage supply, it adopts ModBus RTU protocol, supporting address/baud rate setting and 2000m long-distance communication. Featuring a waterproof wall-mounted design, it suits harsh environments like warehouses, workshops, chemical plants, and greenhouses. Optional OLED screen enables on-site reading. Ideal for real-time gas and environmental monitoring, it’s your reliable choice for diverse industrial and commercial needs.
ZONEWU Ammonia(NH3) Monitoring Transmitter Industrial RS485 Electrochemical Ammonia Gas Transmitter
This RS485-type ammonia temperature and humidity transmitter adopts the electrochemical principle, supports 5-28VDC wide voltage power supply, and features a wall-mounted waterproof design suitable for harsh environments. It has the characteristics of fast response, high sensitivity, and strong anti-interference. Calibrated with exclusive algorithms and standard gases, it has high precision and strong stability, with data updated every 2 seconds. It can real-time monitor ammonia (0-50/100ppm), temperature (-40~80℃), and humidity (0~99.9% RH), and is suitable for scenarios such as farms, chemical plants, and greenhouses. It supports the ModBus RTU protocol and is easy to install and use.
ZONEWU Hydrogen(H2) Monitoring Transmitter Industrial grade RS485 Hydrogen(H2) Gas Transmitter
Our RS485 hydrogen transmitter integrates high-sensitivity gas detection with stable Modbus RTU communication. It supports remote monitoring and PLC system integration, features explosion-proof design and temperature compensation, and delivers accurate H₂ concentration data for industrial sites, battery rooms, and fuel cell systems. Reliable, easy to calibrate, ideal for safety-critical applications.
ZONEWU H2S Gas Transmitter Low Power RS485 Electrochemical H2S Gas Sensor
This RS485 Hydrogen Sulfide Transmitter is an industrial-grade gas detection device based on electrochemical sensing technology. It accurately measures hydrogen sulfide concentrations in the range of 0~50 ppm, while simultaneously monitoring temperature (-40~+80℃) and humidity (0~99.9% RH). Equipped with an RS485 interface and ModBusRTU protocol, it supports a wide voltage supply of 5~28VDC, weighs only 0.6kg, and operates stably in environments ranging from -20~60℃, making it ideal for industrial hydrogen sulfide monitoring scenarios.
Explosion-Proof RS485 CH4 Gas Sensor RS485 MODBUS-RTU CH4 Sensor Explosion-Proof Industry
ZONEWU the methane transmitter designed by our company has strong safety, fast response speed, and strong anti-interference ability. After our company's unique compensation algorithm and multi-stage standard gas calibration, it also has the characteristics of long life, high precision, high repeatability, and high stability. Suitable for real-time monitoring of methane concentration in underground pipe galleries, underground parking lots, public toilets, garages, workshops, chemical plants, greenhouse farms, and other places. The device adopts a wide voltage 10-30V DC power supply, 485 signal output, standard ModBus RTU communication protocol, ModBus address can be set, baud rate can be changed, and the communication distance is up to 2000 meters.
Subscribe to Our Newsletter
Sign up for our company lastest news!
Get A Free Quote
Get A Free Quote
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.

Home

Products

about

contact